C00100 | firmware version, C00101 | add. accel. time x, C00103 | add. decel. time x – Lenze 8400 StateLine User Manual
Page 621: C00105 | decel. time - quick stop, C00105, Time parameterised in, C00101/1, C00103/1, 15 parameter reference
![background image](/manuals/566309/621/background.png)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
621
15
Parameter reference
15.2
Parameter list | C00100
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00100
C00101
C00103
C00105
Parameter | Name:
C00100 | Firmware version
Data type: UNSIGNED_8
Index: 24475
d
= 5F9B
h
Display of the firmware version of the device, divided into subsections.
Display range
(min. value | unit | max. value)
0
99
Subcodes
Info
C00100/1
Firmware version - main version
C00100/2
Firmware version - subversion
C00100/3
Firmware version - release
C00100/4
Firmware version - build
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00101 | Add. accel. time x
Data type: UNSIGNED_32
Index: 24474
d
= 5F9A
h
: FB: Additional acceleration times for the main setpoint
• The additional acceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the
FB.
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00101/1
0.000 s
Add. accel. time 1 ... 15
C00101/...
C00101/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00103 | Add. decel. time x
Data type: UNSIGNED_32
Index: 24472
d
= 5F98
h
FB: Additional deceleration times for the main setpoint
• The additional deceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the
FB.
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00103/1
0.000 s
Add. decel. time 1 ... 15
C00103/...
C00103/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00105 | Decel. time - quick stop
Data type: UNSIGNED_32
Index: 24470
d
= 5F96
h
The set deceleration time determines the ramp slope at quick stop
Activate/deactivate quick stop
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.900 2.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000