6i/o terminals – Lenze 8400 StateLine User Manual
Page 274
![background image](/manuals/566309/274/background.png)
6
I/O terminals
6.1
Digital terminals
274
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Outputs
Identifier
DIS code | data type
Information/possible settings
Counting input DI1
bCountIn1_ResetCompare
BOOL
Reset status signal "Comparison value reached"
FALSETRUE The output bCountIn1_Compare is reset to FALSE.
bCountIn1_LoadStartValue
BOOL
Load starting value into counter
FALSETRUE The starting value set in
is accepted as the current count
value.
Frequency input DI1/DI2
Output of the encoder position of the DI1/DI2 frequency input
bPosIn12_Load
BOOL
(from version 06.00.00)
Load angle integrator with starting value and reset status signal
TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and
bPosIn12_State is reset to FALSE.
dnPosIn12_Set_p
DINT
(from version 06.00.00)
Starting value for angle integrator
Identifier
DIS code | data type
Value/meaning
bCInh
| BOOL
RFR digital input (controller enable)
Digital inputs DI1 ... DI4
Using DI1 and DI2 as digital inputs
bIn1 ... bIn4
| BOOL
Digital input DI1 ... DI4
Counting input DI1
bCountIn1_Compare
BOOL
Status signal "Comparison value reached"
FALSE Current count value < comparison value (
)
TRUE Current count value ≥ comparison value (
)
wCountIn1_HW
wCountIn1_LW
| WORD
Current count value
• Output as High and Low word (without sign)
• Possible counting range: 0 ... 2
31
- 1
Frequency input DI1/DI2
Using DI1 and DI2 as frequency inputs
nFreqIn12_a
| INT
Output frequency as scaled analog signal in [%]
nFreqIn12_v
| INT
Output frequency as speed signal in [inc/ms]
dnPosIn12_p
DINT
(from version 06.00.00)
Angle output signal
• 65536 [incr.] ≡ 1 encoder revolution
• Overflow is possible (display via bPosIn12_State)
bPosIn12_State
BOOL
(from version 06.00.00)
Status signal "Overflow occurred/distance processed"
• Status signal can be reset via bPosIn12_Load.
TRUE Overflow has occurred or distance is processed.