L_Interpolator_1: Speed-up
Linear value
23622
5C46
E
1
UNSIGNED_8
1
Max. motor speed
Linear value
23610
5C3A
E
1
UNSIGNED_16
1
VFC: Time const. slip comp.
Linear value
23609
5C39
E
1
UNSIGNED_16
1
VFC: Frequency interpol. point n
Linear value
23608
5C38
A
11
INTEGER_16
10
VFC: Voltage interpol. point n
Linear value
23607
5C37
A
11
UNSIGNED_16
100
Motorparameter
Linear value
23606
5C36
A
1
UNSIGNED_8
1
VFC: V/f +encoder limitation
Linear value
23604
5C34
A
2
UNSIGNED_16
100
VFC: Vp V/f +encoder
Linear value
23603
5C33
E
1
UNSIGNED_16
1000
VFC: Ti V/f +encoder
Linear value
23602
5C32
E
1
UNSIGNED_16
10
VFC-ECO: Vp CosPhi controller
Linear value
23600
5C30
E
1
UNSIGNED_16
1000
VFC-ECO: Ti CosPhi controller
Linear value
23599
5C2F
E
1
UNSIGNED_16
10
VFC-ECO: Minimum voltage V/f
Linear value
23598
5C2E
E
1
INTEGER_16
100
VFC-ECO: Voltage reduction
Linear value
23597
5C2D
E
1
INTEGER_16
1
Cosine phi
Linear value
23596
5C2C
A
2
INTEGER_16
100
Output power
Linear value
23595
5C2B
A
2
INTEGER_32
1000
Energy display
Linear value
23594
5C2A
A
2
INTEGER_32
100
VFC-ECO: Voltage reduction ramp
Linear value
23593
5C29
E
1
UNSIGNED_8
10
Delay
Linear value
23592
5C28
A
2
UNSIGNED_16
1
SLVC: Field current controller gain
Linear value
23590
5C26
E
1
INTEGER_16
100
SLVC: Cross current controller gain
Linear value
23589
5C25
E
1
INTEGER_16
100
Inverter motor brake: nAdd
Linear value
23588
5C24
E
1
INTEGER_16
1
Inverter motor brake: PT1 filter time
Linear value
23587
5C23
E
1
INTEGER_16
10
Restart on the fly: Flying restart frequency
fd_add
Linear value
23586
5C22
A
1
INTEGER_16
100
Flying restart fct.: Activate
Selection list
23585
5C21
E
1
UNSIGNED_8
1 CINH
Flying restart fct.: Process
Selection list
23584
5C20
E
1
UNSIGNED_16
1
Flying restart fct.: Start frequency
Linear value
23583
5C1F
E
1
INTEGER_16
1
Flying restart fct: Int. time
Linear value
23582
5C1E
E
1
UNSIGNED_16
10
Flying restart fct.: Current
Linear value
23581
5C1D
E
1
INTEGER_16
100
SLPSM: Controlled current setpoint
Linear value
23580
5C1C
A
2
UNSIGNED_16
100
SLPSM: Switching speed
Linear value
23579
5C1B
A
2
INTEGER_16
100
SLPSM: Filter cutoff frequency
Linear value
23578
5C1A
E
1
INTEGER_16
100
SLPSM: Filter time rotor position
Linear value
23577
5C19
A
2
INTEGER_16
10
SLPSM: PLL gain
Linear value
23576
5C18
E
1
INTEGER_16
1
MCTRL: Status
Bit coded
23575
5C17
E
1
UNSIGNED_16
1
Manual entry of motor type
Selection list
23574
5C16
A
1
UNSIGNED_8
1
LS_WriteParamList: Execute Mode
Selection list
23493
5BC5
E
1
UNSIGNED_8
1
LS_WriteParamList: Error status
Linear value
23492
5BC4
E
1
UNSIGNED_16
1
LS_WriteParamList: Error line
Linear value
23491
5BC3
E
1
UNSIGNED_8
1
LS_WriteParamList: Index
Linear value
23490
5BC2
A
32
INTEGER_32
1000
LS_WriteParamList: WriteValue_1
Linear value
23489
5BC1
A
32
INTEGER_32
1
LS_WriteParamList: WriteValue_2
Linear value
23488
5BC0
A
32
INTEGER_32
1
LS_WriteParamList: WriteValue_3
Linear value
23487
5BBF
A
32
INTEGER_32
1
LS_WriteParamList: WriteValue_4
Linear value
23486
5BBE
A
32
INTEGER_32
1
LS_ParReadWrite 1-3: Index
Linear value
23485
5BBD
A
3
INTEGER_32
1000
LS_ParReadWrite 1-3: Cycle time
Selection list
23484
5BBC
A
3
UNSIGNED_16
1
LS_ParReadWrite 1-3: FailState
Linear value
23483
5BBB
A
3
UNSIGNED_16
1
LS_ParReadWrite 1-3: Arithmetic mode
Selection list
23482
5BBA
A
3
UNSIGNED_8
1
LS_ParReadWrite 1-3: Numerator
Linear value
23481
5BB9
A
3
INTEGER_16
1
LS_ParReadWrite 1-3: Denominator
Linear value
23480
5BB8
A
3
INTEGER_16
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)