C00594 | resp. to control word error, C00595 | mck: resp. to mck error, C00594/1 – Lenze 8400 StateLine User Manual
Page 710: C00594/2, 15 parameter reference
15
Parameter reference
15.2
Parameter list | C00594
710
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00594
C00595
Parameter | Name:
C00594 | Resp. to control word error
Data type: UNSIGNED_8
Index: 23981
d
= 5DAD
h
Configuration of device control monitoring
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning
Subcodes
Lenze setting
Info
C00594/1
1: Fault
Response if error bit 14 in the CAN control word is set.
C00594/2
1: Fault
Response if error bit 14 in the MCI control word is set.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00595 | MCK: Resp. to MCK error
Data type: UNSIGNED_8
Index: 23980
d
= 5DAC
h
Configuration of monitoring of the Motion Control Kernel
Selection list
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00595/1
0: No Reaction
Reserved
C00595/2
0: No Reaction
Reserved
C00595/3
0: No Reaction
Reserved
C00595/4
0: No Reaction
Reserved
C00595/5
0: No Reaction
Reserved
C00595/6
0: No Reaction
Reserved
C00595/7
0: No Reaction
Reserved
C00595/8
0: No Reaction
Reserved
C00595/9
0: No Reaction
Reserved
C00595/10
0: No Reaction
Reserved
C00595/11
0: No Reaction
Reserved
C00595/12
0: No Reaction
Reserved
C00595/13
0: No Reaction
Reserved
C00595/14
0: No Reaction
Reserved
C00595/15
1: Fault
Response to activated connection monitoring in case of
PC manual control
•
From version 11.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1