C00937 | field-oriented motor currents, C00939 | ultimate motor current, C00950 | l_interpolator_1: activation fb functions – Lenze 8400 StateLine User Manual
Page 765: C00939, This ensu, C00938, C00937/1, C000937/1, Value set in, 15 parameter reference

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
765
15
Parameter reference
15.2
Parameter list | C00937
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00937
C00938
C00939
C00950
Parameter | Name:
C00937 | Field-oriented motor currents
Data type: INTEGER_16
Index: 23638
d
= 5C56
h
From version 11.00.00
Field weakening for synchronous motors
Display range
(min. value | unit | max. value)
-320.00
A
320.00
Subcodes
Info
C00937/1
Field-producing current
C00937/2
Torque-producing current
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00938 | PSM: Maximum motor current field weakening
Data type: UNSIGNED_16
Index: 23637
d
= 5C55
h
From version 11.00.00
Field weakening for synchronous motors
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
500.00 30.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00939 | Ultimate motor current
Data type: UNSIGNED_16
Index: 23636
d
= 5C54
h
From version 10.00.00
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
A
3000.0 3000.0 A
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00950 | L_Interpolator_1: Activation FB functions
Data type: UNSIGNED_8
Index: 23625
d
= 5C49
h
From version 04.00.00
FB: Activation of signal interpolation and signal monitoring
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00950/1
0: Off
: Signal interpolation
C00950/2
0: Off
: Signal monitoring
C00950/3
0: Off
: Master value monitoring
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1