2 parameter setting, Parameter setting, 8basic drive functions (mck) – Lenze 8400 StateLine User Manual
Page 405: Danger
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
405
8
Basic drive functions (MCK)
8.4
Holding brake control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4.2
Parameter setting
How to go to the parameterisation dialog of the holding brake control:
1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the "Basic functions" button.
4. Go to the Overview Basic functions dialog box and click the Holding brake control button.
Short overview of parameters for holding brake control:
Danger!
A faultless brake control function requires a correct setting of the different deceleration
times in the following parameters!
A wrong setting of the delay times can cause a faulty control of the brake!
Parameter
Info
Lenze setting
Value Unit
Holding brake: Operating mode
0: Brake control off
Holding brake: Switching threshold
5.00 %
Holding brake: Hyst. release
1.00 %
Holding brake: Hyst. close
1.00 %
Holding brake: FF control starting value 1
0 %
Holding brake: FF control starting value 2
0 %
Holding brake: Setting
0
Highlighted in grey = display parameter