C00635 | l_nset_1: nmaxlimit, C00636 | l_nset_1: nminlimit, C00637 | l_nset_1: output blocking zones – Lenze 8400 StateLine User Manual
Page 724: C00638 | l_nset_1: output ramp rounding, C00639 | l_nset_1: output additional value, C00635, C00636, 15 parameter reference
![background image](/manuals/566309/724/background.png)
15
Parameter reference
15.2
Parameter list | C00635
724
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00635
C00636
C00637
C00638
C00639
Parameter | Name:
C00635 | L_NSet_1: nMaxLimit
Data type: INTEGER_16
Index: 23940
d
= 5D84
h
FB: Maximum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00636 | L_NSet_1: nMinLimit
Data type: INTEGER_16
Index: 23939
d
= 5D83
h
FB: Minimum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 -199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00637 | L_NSet_1: Output blocking zones
Data type: INTEGER_16
Index: 23938
d
= 5D82
h
FB: Speed setpoint is displayed after being processed by blocking zone function
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00638 | L_NSet_1: Output ramp rounding
Data type: INTEGER_16
Index: 23937
d
= 5D81
h
FB: Speed setpoint is displayed after being processed by PT1 filter function
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00639 | L_NSet_1: Output additional value
Data type: INTEGER_16
Index: 23936
d
= 5D80
h
FB: Additional speed setpoint is displayed after being processed by the ramp generator
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100