APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.4 Using Contact I/O Signals

78

J

Contact Output Signal Terminal Connections

These output signals are used

to indicate SGDB SERVOPACK

operation status.

SGDB SERVOPACK

Photocoupler

Host

controller

I/O power

supply

Photocoupler output
Per output
Maximum operational

voltage: 30 VDC

Maximum output

current: 50 mA DC

Open collector output
Per output
Maximum operational

voltage: 30 VDC

Maximum output

current: 20 mA DC

/V-CMP+

/V-CMP−

/TGON+

/TGON−
/S-RDY+

/S-RDY−

Note Provide an external I/O power supply separately.

There are no power terminals to which the SGDB SERVOPACK outputs signals
externally.
Yaskawa recommends that this external power supply be the same type as for the
input circuit.