Yaskawa SGDB User Manual
Page 213

USING THE DIGITAL OPERATOR
4.2.3 Autotuning cont.
202
1. Press the
DSPL
SET
(or
MODE/SET
) key to cancel autotuning.
2. Press the
DSPL
SET
(or
MODE/SET
) key once more to enter the machine rigidity setting
mode. Reduce the setting by one.
• If Autotuning Does Not End
Failure of autotuning to end
, is caused by an inappropriate machine rigid-
ity setting. Follow the procedure below to correct the machine rigidity setting, and run
autotuning once more.
1. Press the
DSPL
SET
(or
MODE/SET
) key to cancel autotuning.
2. Press the
DSPL
SET
(or
MODE/SET
) key once more to enter the machine rigidity setting
mode. Increase the setting by one.
Autotuning may not end for machines with large play or extremely low rigidity.
In these cases, use conventional manual adjustment.
Input Signals
• The P-OT signal, N-OT signal and SEN signal (absolute encoder only) are enabled
during autotuning. Input the P-OT signal, N-OT signal and SEN signal (absolute
encoder only) during autotuning.
To conduct autotuning without inputting these signals, set parameter Cn-01 Bits 1, 2,
and 3 to 1.
• Autotuning is not possible during overtravel
(P-OT or N-OT signal OFF).
• Conduct autotuning when no overtra-
vel has occurred (both P-OT and
N-OT signal ON).
4
Load
Load
OFF
ON
Motor
Motor
ON
ON