Yaskawa SGDB User Manual
Page 203

USING THE DIGITAL OPERATOR
4.1.7 Operation in Monitor Mode cont.
192
J
Monitor Mode Displays
Monitor
Number
Monitor Display
Actual motor speed Units: min
−1
.
Input speed reference
Units: min
−1
.
Internal torque reference
Units: %
(with respect to rated torque)
Number of pulses from motor U-phase edge
Units: pulses
Electrical angle
Units: 0.1 deg
Internal status bit display
Internal status bit display
Input reference pulse speed display
Units: min
−1
.
Positional error
Units: x1 reference unit (Cn-02 Bit E = 0)
x100 reference unit (Cn-02 Bit E = 1)
Reference pulse counter reading
Units: reference units
A value between 0 to 65535 inclusive is
displayed.
Monitor
No
Bit
No
Description
Related I/O Signal, Parameter
Un-05
1
Servo alarm
1CN-31 (ALM)
2
Dynamic brake ON
3
Reverse rotation mode
Cn-02 Bit 0, 2CN-7 (DIR)
4
During motor rotation
5
Speed coincidence or positioning
complete
6
Mode switch ON
7
During forward
current limit
Or contact input
speed control
1CN-45 (/P-CL)
8
During reverse
current limit
speed co o
1CN-46 (/N-CL)
9
Motor power ON
10
A-phase
2CN-16(PA), 2CN-17(/PA)
11
B-phase
2CN-18(PB), 2CN-19(/PB)
12
C-phase
2CN-14(PC), 2CN-15(/PC)
13
U-phase
14
V-phase
15
W-phase
16
Servo ON
1CN-40 (/S-ON)
17
P operation or rotation direction input
1CN-41 (/P-CON)
18
Forward overtravel
1CN-42 (P-OT), Cn-01 Bit 2
19
Reverse overtravel
1CN-43 (N-OT), Cn-01 Bit 3
20
SEN signal input
1CN-4 (SEN), Cn-01 Bit 1
4
Internal Status
Bit Display
20