INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.1 Troubleshooting Problems with Alarm Display cont.

524

J

A.F1

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.F1

Power line open

phase

OFF

ON

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

A, B

At main circuit power

supply ON.

Occurred when the control

power turned ON.

C

Cause

Remedy

A

One phase (R,S,T) of the main circuit

power supply is disconnected.

• Check power supply.
• Check wiring of the main circuit power sup-

ply.

• Check MCCB, noise filter, magnetic con-

tactor.

B

There is one phase where the line voltage

is low.

Check power supply.

C

SERVOPACK defective.

Replace SERVOPACK.