Yaskawa SGDB User Manual
Page 41

2.2 Installation
29
Power loss
Power loss of SERVOPACK is given below:
Power loss for rated output
SERVOPACK
type
Output
current
(RMS value)
A
Power loss
in main
circui
t
W
Power loss
of
regenerative
resistor W
Power loss
in control
circuit
W
Power loss
in total
W
SGDB-03ADj
3.0
18
30
20
68
SGDB-05ADj
3.8
27
77
SGDB-07ADj
5.7
41
91
SGDB-10ADj
7.6
55
105
SGDB-15ADj
11.6
80
130
SGDB-20ADj
18.5
120
170
SGDB-30ADj
24.8
170
22
222
SGDB-44ADj
32.9
250
60
24
334
SGDB-50ADj
28.2
260
344
SGDB-60ADj
46.9
290
27
317
SGDB-75ADj
54.7
330
-
357
SGDB-1AADj
58.6
360
30
390
SGDB-1EADj
78.0
490
520
Note a) Power loss of regenerative resistor is allowable loss. If the loss exceeds the
allowable loss, the regenerative resistor inside the SERVOPACK should be
removed and connected externally. Because the model in which the regenera-
tive resistor is externally connected falls into non-standard specification cate-
gories, contact YASKAWA for further information.
For this non-standard type, “Y8” is appended to the end of the standard model
number.
b) For SGDB-60AD to 1EADj models, the regenerative resistor is placed sepa-
rately. The regenerative resistor unit provided from YASKAWA is described in
Section 3.8.4 Using Regenerative Resistor Units. Its power loss for
SGDB-60ADj is 180W (type: JUSP-RA04), and for SGDB-75ADj and
-1EADj is 350W(type: JUSP-RA05).
2