beautypg.com

13 surge suppressor, 14 regenerative resistor unit – Yaskawa SGDB User Manual

Page 500

background image

SERVO SELECTION AND DATA SHEETS

5.6.14 Regenerative Resistor Unit

490

5.6.13 Surge Suppressor

Attach a surge suppressor to the magnetic contactor to prevent power supply noise and
protect contacts.

• Recommended Product

Spark Killer manufactured by Okaya Electric Industries Co., Ltd.
Type: CR50500BA (250 VAC)
Capacitance: 0.5 μF  20%
Resistance: 50 Ω (1/2 W) 30%

5.6.14 Regenerative Resistor Unit

For SERVOPACKs (SGDB-60 or higher) for use with motors with 5.5 kW or more,
externally attach a regenerative resistor to the SERVOPACK. This resistor is used for
dissipating regenerative energy.

Use one of the following regenerative resistor units according to the SERVOPACK type:

SGDB SERVOPACK Type

Regenerative Resistor Unit Type

60ADj

JUSP-RA04

75ADG

JUSP-RA05

1AADG
1EADG

• Dimensional Drawings

(4-Ø0.24)

Mounting Hole

Protective Cover

Ground Terminal

(M4 Screw)

External Terminal

(M5 Screw)

220W, 25Ω Cement Resistor

(4 or 8 Resistors Connected in

Parallel)

(1.18)

5