USING THE DIGITAL OPERATOR
4.2.5 Reference Offset Manual Adjustment Mode cont.
212
9. Press
DSPL
SET
to return to the parameter data
display.
10.Press
DATA
ENTER
to return to the setting mode dis-
play. This ends the reference offset manual ad-
justment.
For JUSP-OP03A
1. Press
MODE/SET
to select the parameter setting
mode.
2. Press the
UP
and
DOWN
keys to select the pa-
rameter number Cn-00.
(Parameter Cn-00 is selected when the power
is turned ON.)
3. Press
DATA
to display the current data for the pa-
rameter Cn-00.
4. Press the
UP
and
DOWN
keys to change the
data to 03.
5. Press
MODE/SET
to select the speed reference off-
set manual adjustment mode.
The amount of speed reference offset is dis-
played.
6. Press the
UP
and
DOWN
keys to adjust the
amount of offset.
(Adjust the speed references.)
7. Press
MODE/SET
to select the torque reference off-
set manual adjustment mode.
The amount of torque reference offset is dis-
played.
8. Press the
UP
and
DOWN
keys to adjust the
amount of offset.(Adjust the torque references.)
4
Setting Mode Display
JUSP-OP03A
Setting Mode
Select Cn-00.
Parameter Number
Data
Set to 00-03.
Value changes
rapidly when
key held down.
Speed Reference
Offset Manual
Adjustment Mode
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)