2.2 Installation

27

2.2.5 Installing the SERVOPACK

Σ-Series SGDB SERVOPACK is a base-mount type
servo controller.
Incorrect installation will cause problems. Always ob-
serve the installation instructions described below.

Storage:

When the SERVOPACK is to be stored with the
power cable disconnected, store it in the following
temperature range:

Between −20°C and 85°C

Installation sites:

Situation

Notes on Installation

When installed in a control panel

Design the control panel size, unit layout, and cooling
method so that the temperature around the periphery of
the SERVOPACK does not exceed 55°C.

When installed near a heating
unit

Suppress radiation heat from the heating unit and a
temperature rise caused by convection so that the
temperature around the periphery of the SERVOPACK
does not exceed 55°C.

When installed near a source of
vibration

Install a vibration isolator underneath the SERVOPACK
to prevent it from receiving vibration.

When installed in a place
receiving corrosive gases

Corrosive gases do not immediately affect the
SERVOPACK but will eventually cause contactor-related
devices to malfunction. Take appropriate action to
prevent corrosive gases.

Others

Avoid installation in a hot and humid place or where
excessive dust or iron powder is present in the air.

Orientation:

Install the SERVOPACK perpendicular to the wall
as shown in the figure.

The SERVOPACK must be orientated as shown
in the figure.

• Firmly secure the SERVOPACK through four

mounting holes.

2

SGDB SERVOPACK

Ventilation