USING THE DIGITAL OPERATOR

4.2.2 Operation Using the Digital Operator cont.

200

6. Press

DATA

to set the servo ON status (motor

power turned ON).

7. Press the

UP

and

DOWN

keys to operate the mo-

tor.

8. Press

MODE/SET

to revert to

. This sets

the servo OFF status (motor power turned
OFF).

9. Press

DATA

to return to the setting mode display.

This disables operation under Digital Operator
control.

J

Changing Motor Speed

The motor speed for operation under Digital Operator control can be changed with a pa-
rameter:

Parameter: Cn-10 (JOGSPD), Units: min

−1

., Standard setting: 500

For details about setting the motor speed, refer to Section 4.1.6 Operation in Parameter
Setting Mode
and Appendix C List of Parameterts.

4

to change.

Servo ON

- motor ON

Servo OFF

- base block

Press

DATA

Motor runs

forward while

this key is

pressed.

Motor runs

backward while

this key is

pressed.

Motor

Forward

Rotation

Motor

Reverse

Rotation

Setting Mode Display