3 resetting servo alarms – Yaskawa SGDB User Manual
Page 191
USING THE DIGITAL OPERATOR
4.1.3 Resetting Servo Alarms
180
Mounted Digital Operator
Key
Name
Function
UP
UP Key
Press to display the parameter settings and
set values.
Pressing the UP Key increments the set val-
ue.
DOWN
DOWN Key
Pressing the DOWN Key decrements the set
value.
Servo alarms can be reset by pressing the
UP Key and DOWN Key simultaneously.
MODE/SET
MODE/SET Key Press to select the status display mode, set-
ting mode, monitor mode, or error trace-
back mode.
DATA
DATA Key
Press to display the parameter settings and
set values.
Can be used as a data setting key in the set-
ting mode.
4.1.3 Resetting Servo Alarms
Servo alarms can be reset using the Digital Operator. (Servo alarms can also be reset by the
1CN-44, /ALMRST input signal. Refer to Section 3.7.1 Using Servo Alarm Output and Alarm
Code Output for details.)
The alarm state can be cleared by turning the main power supply OFF, then turning the con-
trol power supply OFF.
Type: JUSP-OP02A-1
Press
Type: JUSP-OP03A
simultaneously
.
Alarm Reset
Press
Alarm Reset
NOTE
After an alarm occurs, remove the cause of the alarm before resetting it. Refer to Section
6.2 Troubleshooting to determine and remedy the cause of an alarm.
4