Yaskawa SGDB User Manual
Page 201

USING THE DIGITAL OPERATOR
4.1.6 Operation in Parameter Setting Mode cont.
190
8. Press
DATA
ENTER
once more to display the parameter
number again.
Refer to Appendix C List of Parameters.
For JUSP-OP03A
1. Press
MODE/SET
to select the parameter setting
mode.
2. Press the
UP
and
DOWN
keys to select the pa-
rameter number to set.
3. Press
MODE/SET
to display the current data for the
memory switch selected at step 2.
4. Press the
UP
and
DOWN
keys to select the bit
number to set.
5. Press
MODE/SET
to set the memory switch data
ON or OFF for the bit number.
6. Repeat steps 4 and 5 as often as required.
7. Press
DATA
to store the data.
8. Press
DATA
once more to display the parameter
number again.
Refer to Appendix C List of Parameter Settings
4
Parameter
Number
Memory
Switch Data
JUSP-OP03A
Setting
Mode
Parameter
Number
Memory
Switch Data
Bit
Number
to Set
Bit Number to Set
Bit
Number
The stored data
flashes.
Parameter
Number
Memory
Switch Data
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)