INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.1 Troubleshooting Problems with Alarm Display cont.

506

J

A.10

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.10

Overcurrent

ON

OFF

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

During servomotor

operation

When servo ON (/S-ON)

signal turned ON

A

,

B

, D

C,

D

At power ON

C

Cause

Remedy

A

Wiring grounded between SERVOPACK

and servomotor.

Check and correct wiring.

B

Servomotor U, V, or W phase grounded.

Replace servomotor.

C

• Circuit board (1PWB) defective
• Power transistor defective

Replace SERVOPACK.

D

Current feedback circuit, power transistor,

DB circuit, or circuit board defective.

Replace SERVOPACK.