beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 73

background image

TNC 425/TNC 415 B/TNC 407

4-14

4

Programming

4.3

Tools

Fig. 4.8:

Pocket table for the tool changer

Pocket table for tool changer

The TOOL_P table (for tool pocket) is programmed
in a program run operating mode.

The NEW POCKET TABLE or also the RESET POCKET
TABLE soft key is for erasing an existing pocket table
and writing a new one. Like the tool table, a pocket
table can also be read-in and read-out directly through
the data interface (see page 4-11).

To select the pocket table:

Select tool table.

Select pocket table.

Set the EDIT soft key to ON.

To edit the pocket table:

Abbrev.

Input

Dialog

P

Pocket number of the tool in the tool magazine

T

Tool number

TOOL NUMBER

F

Fixed tool number. The tool is always returned to the same pocket.

FIXED TOOL
YES = ENT / NO = NOENT

L

Locked pocket

POCKET LOCKED
YES = ENT / NO = NOENT

ST

Special Tool
If this ST requires also the pockets in front of and behind
its own pocket, then lock the appropriate number of pockets.

SPECIAL TOOL

PLC

Information on this tool that should be sent to the PLC

PLC STATUS

Overview: Data in the pocket table