9-29

TNC 425/TNC 415 B/TNC 407

9

3D Touch Probe Systems

3

e.g.

ENT

X

e.g.

TOUCH
PROBE

GOTO

6

ENT

ENT

1

ENT

.

.

.

0

9.4

Digitizing with a Measuring Touch Probe

Input data

• LINE DIRECTION

Coordinate axis in whose positive direction the touch probe moves
from the first contour point.

• SCANNING ANGLE

Traversing direction of the touch probe referenced to the LINE
DIRECTION.
Input range: -90° to +90°

• FEED RATE F

Enter the digitizing speed.
Input range: 1 to 3000 mm/min
The greater the digitizing speed, the less accurate the data resulting
from digitizing will be.

• MIN. LINE SPACING

If you enter an input value that is smaller than the programmed LINE
SPACING the TNC decreases the spacing between the scanned lines
to the programmed minimum for digitizing steep sections of a con-
tour. This ensures that the density of digitized positions remains
constant even if complex surface structures are scanned.
Input range: 0 to 20 mm

• LINE SPACING

The offset by which the probe moves at the end of each line before
scanning the next line.
Input range: 0 to 20 mm

• MAX. PROBE POINT INTERVAL

Maximum spacing between consecutive digitized positions. The TNC
also accounts for important points that define the contour of the
model, for example at inside corners.
Input range: 0.02 to 20 mm

• TOLERANCE

The TNC only stores digitized positions whose distance from a straight
line defined by the last two probe points exceeds the programmed
tolerance. This way a high density of digitized positions is output for
contours with sharply curved surfaces while as few positions as
possible are stored for contours with flat surfaces. The input value 0
means that the digitized positions are output in the programmed
probe point interval.
Input range: 0 to 0.9999 mm

To program TCH PROBE 16.0:

TCH PROBE 0 REF. PLANE

Select digitizing cycle 16 MEANDER.

TCH PROBE 16 MEANDER

Confirm your selection.

LINE DIRECTION ?

Enter the axis of the X/Y plane parallel to which the touch probe
should move.

SCANNING ANGLE ?

Enter the angle between the path of traverse of the touch probe and
the programmed LINE DIRECTION.