beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 297

background image

TNC 425/TNC 415 B/TNC 407

9-30

9

3D Touch Probe Systems

Before cycle 16: MEANDER, the program must have a range defined in cycle 5: RANGE or cycle 15: RANGE
(TABLE).

.

.

.

e.g.

1

0 0

0

ENT

Resulting NC blocks:

TCH PROBE

16.0 MEANDER

TCH PROBE

16.1 DIRECTN: X

ANGLE
TCH PROBE

16.2 F1000 MIN.L.SPAC: 0.2

L.SPAC: 0.5 PP.INT: 0.5 TOL: 0.1

e.g.

0

ENT

2

e.g.

0

ENT

5

e.g.

0

ENT

5

e.g.

0

ENT

1

9.4

Digitizing with a Measuring Touch Probe

TOLERANCE ?

Enter the diameter of the tubular tolerance zone, for example
0.1 mm.

MAX. PROBE POINT INTERVAL ?

Enter the maximum probe point interval, for example 0.5 mm.

LINE SPACING ?

Enter the maximum spacing between lines, for example 0.5 mm.

FEED RATE ?

F=

Enter the digitizing speed, for example 1000 mm/min.

MIN. LINE SPACING ?

Enter the minimum spacing between lines, for example 0.2 mm.