3D Touch Probe Systems

e.g.

TOUCH
PROBE

GOTO

5

ENT

Z

ENT

To program TCH PROBE 5.0:

TCH PROBE: 0 REF. PLANE

Select digitizing cycle 5: RANGE.

TCH PROBE: 5 RANGE

Confirm your selection.

PGM NAME DIGITIZING DATA?

Enter the name of the file in which the digitizing data should be stored.

TCH PROBE AXIS?

Enter the touch probe axis.

e.g.

1 0

e.g.

1 0

e.g.

0

2

e.g.

1 0

0

ENT

ENT

ENT

ENT

0

e.g.

0

0

ENT

ENT

ENT

9.5

Digitizing with the TS 120 Touch Probe

MIN. POINT RANGE?

Enter in sequence the X, Y and Z coordinates of the range MIN point.

MAX. POINT RANGE?

Enter in sequence the X, Y and Z coordinates of the range MAX
point.

CLEARANCE HEIGHT?

Enter the clearance height for the touch probe.

Resulting NC blocks:

TCH PROBE

5.0

RANGE

TCH PROBE

5.1

PGM NAME: DATA

TCH PROBE

5.2

Z

X+0 Y+0 Z+0

TCH PROBE

5.3

X+10 Y+10 Z+20

TCH PROBE

5.4

HEIGHT: + 100