beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 275

background image

TNC 425/TNC 415 B/TNC 407

9-8

9

3D Touch Probes



MANUAL OPERATION

ROTATE TOUCH PROBE TO 0 DEGREES

Rotate the touch probe to 0° in the manual mode of operation.

I

Displaying calibration values

The compensation factors and force ratios are
stored in the TNC for use whenever the TM 110 is
needed again. You can display the values on the
screen by pressing the 3D CAL soft key.

Fig. 9.9:

Menu for 3D calibration and center misalignment

9.2

Touch Probe Cycles in the MANUAL and ELECTRONIC HANDWHEEL Operating Modes

Start the calibration cycle once again to determine center misalign-
ment. The touch probe again measures the standard ring gauge in a
programmed sequence of steps.