beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 72

background image

4-13

TNC 425/TNC 415 B/TNC 407

4

Programming

Information in tool tables

(continued)

Abbrev.

Input

Dialog

CUT.

Number of teeth that are measured in automatic tool
measurement (max. 20 teeth)

NUMBER OF TEETH ?

LTOL

Permissible deviation from tool length L during automatic tool
measurement. If the entered value is exceeded, the TNC locks
the tool (status L).
Input range: 0 to 0.9999 mm

WEAR TOLERANCE: LENGTH ?

RTOL

Permissible deviation from tool radius R during automatic tool
measurement. If the entered value is exceeded, the TNC locks
the tool (status L).
Input range: 0 to 0.9999 mm

WEAR TOLERANCE: RADIUS ?

DIRECT.

Automatic tool measurement: Cutting direction of the

tool for dynamic tool measurement

CUTTING DIRECTION ( M3 = – ) ?

TT:R-OFFS

Automatic tool length measurement: Offset of the tool

between the stylus center and the tool center.
Default setting: tool radius R

TOOL OFFSET: RADIUS ?

TT:L-OFFS

Automatic tool radius measurement: tool offset in addition
to the value in MP 6530 (see S. 12-6) between the
stylus top and the tool tip.
Default setting: 0

TOOL OFFSET: LENGTH ?

LBREAK

Automatic tool measurement: permissible deviation from
the tool length L for breakage detection. If the entered value
is exceeded, the TNC locks the tool
(Status L). Input range: 0 to 0.9999 mm

BREAKAGE TOLERANCE: LENGTH ?

RBREAK

Automatic tool measurement: permissible deviation from
the tool length R for breakage detection. If the entered value
is exceeded, the TNC locks the tool
(Status L). Input range: 0 to 0.9999 mm

BREAKAGE TOLERANCE: RADIUS ?

4.3

Tools