12.1 General User Parameters

Programming station

MP7210

TNC with machine:

0

TNC as programming station with active PLC:

1

TNC as programming station with inactive PLC:

2

Acknowledgement of POWER INTERRUPTED message

MP7212

Acknowledge with key:

0

Automatic acknowledgment:

1

Block number increment for ISO programming

MP7220

0 to 150

Maximum length of file names

MP7222

8 characters:

0

12 characters:

1

16 characters:

2

Inhibit file management for certain file types

MP7224.0

No files inhibited:

+0

Inhibit HEIDENHAIN programs: +1
Inhibit ISO programs:

+2

Inhibit tool tables:

+4

Inhibit datum tables:

+8

Inhibit pallet tables:

+16

Inhibit text files:

+32

+32

+32

+32

+32

Inhibit PNT table

: +128

: +128

: +128

: +128

: +128

Inhibit editor for certain file types

MP7224.1

Do not inhibit editor:

+0

Inhibit editor for HEIDENHAIN programs:

+1

Inhibit editor for ISO programs:

+2

Inhibit editor for tool tables:

+4

Inhibit editor for datum tables:

+8

Inhibit editor for pallet tables:

+16

Inhibit editor for text files:

+32

Inhibit editor for PNT table

::::: +128

If you inhibit the file types of existing files, those files will be deleted!