HEIDENHAIN TNC 407 (280 580) User Manual User Manual
Page 171
TNC 425/TNC 415 B/TNC 407
5-72
5
Programming Tool Movements
M Functions for Laser Machine Tools
Output voltage as a function of time (time-dependent ramp): M203 V... TIME...
The TNC output the voltage as a function of time. Depending on the active
voltage the TNC increases or decreases the voltage linearly to the value
programmed after V... within the time programmed for TIME.
Input range
Voltage V:
0 to 9.999 volts
TIME:
0 to 1.999 seconds
Duration of effect
M203 V... TIME... is effective at the start of block and remains in effect
until a new voltage is output through M200, M201, M202, M203 or M204.
Output voltage as a function of time (time-dependent pulse): M204 V... TIME...
The TNC outputs the voltage programmed after V... as a pulse. The
duration of the pulse is defined by TIME.
Input range
Voltage V:
0 to 9.999 volts
TIME:
0 to 1.999 seconds
Duration of effect
M204 V... TIME... is effective at the start of block and remains in effect
until a new voltage is output through M200, M201, M202, M203 or M204.