beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 51

background image

TNC 425/TNC 415 B/TNC 407

3-3

3

Test Run and Program Run

3.1

Test Run

ENT

e.g.

5

1 2 3

ENT

e.g.

ENT

1

e.g.

or

To do a test run up to a certain block:

With the STOP AT N function the TNC does a test run up to a certain block
with the block number N.

Select the TEST RUN mode and go to the program beginning.

Select a partial test run.

STOP AT: N

=

PROGRAM

=

REPETITIONS

=

Enter the block number N at which you wish the test to stop.

Enter the name of the program that contains the block with the block
number N.

If N is located in a program section repetition, enter the number of
repetitions that you wish to run.

Test the program up to the entered block.

The display functions for test run

In the TEST RUN operating mode the TNC offers functions for displaying a
program in pages.

Shift the soft-key row.

Function

Soft key

• Go back in the program by one screen

page

• Go forward in the program by one screen

page

• Go to the program beginning

• Go to the program end