beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 349

background image

12-5

12

Tables and Overviews

TNC 425/TNC 415 B/TNC 407

12.1 General User Parameters

MP6300

Reserved

Infeed of TM measuring touch probe stylus

MP6310

0.1 to 2.0000 [mm] (recommended: 1 mm)

Measure center misalignment during calibration of measuring touch probe

MP6321

Measure center misalignment:

0

Do not measure center misalignment:

1

Assignment of touch probe axis to machine axis for measuring touch probe

MP6322.0

Machine axis X is parallel to
Touch probe axis X:

0

Touch probe axis Y:

1

Touch probe axis Z:

2

MP6322.1

Machine axis Y is parallel to
Touch probe axis X:

0

Touch probe axis Y:

1

Touch probe axis Z:

2

MP6322.2

Machine axis Z is parallel to
Touch probe axis X:

0

Touch probe axis Y:

1

Touch probe axis Z:

2

Maximum stylus deflection for measuring touch probe

MP6330

0.1 to 4.0000 [mm]

Feed rate for positioning of measuring touch probe to MIN point and moving to the contour

MP6350

10 to 3000 [mm/min]

Probe feed rate for measuring touch probe

MP6360

10 to 3000 [mm/min]

Rapid traverse in probing cycle for measuring touch probe

MP6361

10 to 3000 [mm/min]

Feed rate reduction if stylus of measuring touch probe is deflected laterally

The TNC reduces the feed rate according to a preset characteristic. The minimum
feed rate is 10% of the programmed digitizing feed rate.

MP6362

Feed rate reduction not active:

0

Feed rate reduction active:

1

Target window for digitizing in contour lines with measuring touch probe

With contour line digitizing, the end points of the individual contour lines are not exactly
the same as the starting points. With machine parameter MP 6390 you can define a
square target window within which the end point must lie after the touch probe has
orbited the model. The input value is half the side length of the target window.

MP6390

0.1 to 4.0000 [mm]

The touch probe axes must be correctly assigned to the machine axes, otherwise
there is danger of stylus breakage.

3D touch probes and digitizing