beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 311

background image

TNC 425/TNC 415 B/TNC 407

9-44

9

3D Touch Probe Systems

0

5

e.g.

ENT

X

e.g.

ENT

TOUCH
PROBE

GOTO

6

ENT

ENT

0

e.g.

ENT

5

0

e.g.

ENT

2

9.5

Digitizing with the TS 120 Touch Probe

LINE SPACING?

Enter the desired spacing between lines, for example 0.2 mm.

MAX. PROBE POINT INTERVAL?

Enter the maximum probe point interval, for example 0.5 mm.

Resulting NC blocks:

TCH PROBE 6.0

MEANDER

TCH PROBE 6.1

DIRECTN: X

TCH PROBE 6.2

TRAVEL: 0.5 L.SPAC: 0.2

PP.INT: 0.5

Before cycle 6: MEANDER, the program must have a range defined in digitizing cycle 5: RANGE.

To program TCH PROBE 6.0:

TCH PROBE: 0 REF. PLANE

Select the digitizing cycle 6 MEANDER.

TCH PROBE: 6 MEANDER

Confirm your selection.

LINE DIRECTION?

Enter the line direction, for example X.

LIMIT IN NORMAL LINES DIRECTION?

Enter the distance of travel by which the probe lifts off the surface
during scanning, for example 0.5 mm.