12-25

12

Tables and Overviews

TNC 425/TNC 415 B/TNC 407

TNC messages during test run and program run

ANGLE REFERENCE MISSING

• Complete your definition of the arc and its end points.
• Define the polar coordinate angle correctly.

ARITHMETICAL ERROR

You have calculated with illegal values.

• Define values within the range limits
• Choose probe positions for the 3D touch probe that are farther apart
• You are using the TT to measure individual teeth on a tool that,

according to the tool table, has 0 teeth. Enter the correct number of
teeth.

• Run the TCH PROBE 30 cycle (calibrating the TT) before measuring

the tool length or radius.

• All calculations must be mathematically possible

AXIS DOUBLE PROGRAMMED

Each axis can have only one value for position coordinates.

BLK FORM DEFINITION INCORRECT

• Program the MIN and MAX points according to the instructions.
• Choose a ratio of sides less than 200:1.

CALIBRATE TOUCH PROBE

The machine parameters for the touch probe were changed. Recalibrate
the touch probe.

CHAMFER NOT PERMITTED

A chamfer block must be located between two straight line blocks with
identical radius compensation.

CIRCLE CENTER UNDEFINED

• Define a circle center with the CC key.
• Define a pole with the CC key.

CIRCLE END POS. INCORRECT

• Enter complete information for connecting circle.
• Enter end points that lie on the circular path.

CYCL INCOMPLETE

• Define the cycles with all data in the proper sequence.
• Do not call the coordinate transformation cycles.
• Define a cycle before calling it.
• Enter a pecking depth other than 0.

12.5 TNC Messages