9-41

TNC 425/TNC 415 B/TNC 407

9

3D Touch Probe Systems

Fig. 9.28:

Clearance height and digitizing
range

9.5

Digitizing with the TS 120 Touch Probe

Y

X

Z

MAX

MIN

S

Z

Defining the digitizing range

The digitizing range is defined in cycle 5 RANGE. The model to be
scanned must lie within this range. The range is programmed – similar to
defining the workpiece blank – by entering the MIN and MAX point
coordinates of the three main axes X, Y and Z.

Input

• PGM NAME DIGITIZING DATA?

Name of the file in which the digitized data is to be stored

• TCH PROBE AXIS ?

Enter the touch probe axis

• MIN. POINT RANGE

Lowest coordinates in the range to be digitized

• MAX. POINT RANGE

Highest coordinates in the range to be digitized

• CLEARANCE HEIGHT

Position in the probe axis at which the stylus cannot collide with the
model