beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 305

background image

TNC 425/TNC 415 B/TNC 407

9-38

9

3D Touch Probe Systems

e.g.

0

ENT

5

Resulting NC blocks:

TCH PROBE 18.0 LINE
TCH PROBE 18.1 DIRECTN: X
ANGLE: 0 HEIGHT: 25
TCH PROBE 18.2 F1000
MIN.L.SPAC: 0.2 L.SPAC: 0.5
PP.INT: 0.5 TOL: 0.1

e.g.

0

ENT

1

Before cycle 18: LINE, the program must have a range defined in cycle 5: RANGE or cycle 15: RANGE (TABLE).

.

.

.

9.4

Digitizing with a Measuring Touch Probe

MAX. PROBE POINT DISTANCE ?

Enter the maximum probe point interval, for example 0.5 mm.

TOLERANCE ?

Enter the diameter of the tubular tolerance zone, e.g. 0.1 mm.