beautypg.com

HEIDENHAIN TNC 407 (280 580) User Manual User Manual

Page 362

background image

12-18

12

Tables and Overviews

TNC 425/TNC 415 B/TNC 407

Overlap factor: Q112

The overlap factor for pocket milling (MP 7430) is assigned to Q112.

Units of measure for dimensions in the part program: Q113

The value of the parameter Q113 specifies whether the highest-level NC
program (for nesting with PGM CALL) is programmed in millimeters or
inches.

Dimensions in the main program

Parameter value

Metric system (millimeters)

Q113 = 0

Inch system (inches)

Q113 = 1

Tool length: Q114

The current value for tool length is assigned to Q114.

Coordinates after probing during program run

The parameters Q115 to Q119 contain the coordinates of the spindle
position at the time of contact during a programmed measurement with
the 3D touch probe. The length and radius of the probe tip are not com-
pensated in these coordinates.

Coordinate axis

Parameter

X axis

Q115

Y axis

Q116

Z axis

Q117

IVth axis

Q118

Vth axis

Q119

Actual-nominal deviation during automatic tool measurement with the TT 110 touch probe

Actual-nominal deviation

Parameter

Tool length

Q115

Tool radius

Q116

12.3 Preassigned Q Parameters