HEIDENHAIN TNC 407 (280 580) User Manual User Manual
Page 373

12-29
12
Tables and Overviews
TNC 425/TNC 415 B/TNC 407
TNC messages during digitizing
AXIS DOUBLE PROGRAMMED
Program two different axes for the coordinates of the starting point
(CONTOUR LINES cycle).
EXCHANGE TOUCH PROBE BATTERY
Change the battery in the probe head (TS 511).
This message is output when the digitizing probe reaches the end of a
line.
FAULTY RANGE DATA
• Enter MIN coordinates that are smaller than their MAX coordinates.
• Define the RANGE within the limits through software limit switches.
• Define the RANGE for the MEANDER and CONTOUR LINES cycles.
MIRRORING NOT PERMITTED
Reset all coordinate transformations before digitizing.
PLANE WRONGLY DEFINED
Define the starting position coordinates (CONTOUR LINES cycle) in axes
different from the stylus axis.
PROBE SYSTEM NOT READY
• Orient the transmission/reception window of the TS 511 towards the
transceiver
• Check whether the touch probe system is ready for operation.
• Touch probe cannot be retracted
• Measuring touch probe: one or more axes of the measuring touch
probe are defective. Contact your service agency.
RANGE EXCEEDED
Enter a RANGE that includes the entire 3D surface to be scanned.