Lenze · Engineer · 2.13 EN - 10/2014

85

Establishing an online connection

Going online

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2.1.5

PROFINET

For the Servo Drives 9400 device series a PROFINET communication module is provided,

by means of which you can establish an online connection to a field device via PROFINET.

6.2.1.6

Gateway controller -> CAN

The controller offers a gateway function to establish an online connection to a field device via CAN.

How to configure an online connection to a field device which is connected to the

controller via CAN:

1. Go to the Communication path dialog box and select the entry "Gateway controller -> CAB"

from the Bus connection list field.

2. Press Search/Enter....

• The Gateway controller -> Set up CAN system bus dialog box is shown:

3. Enter the IP address of the controller.

• By pressing Ping you can carry out a simple test on whether a device can actually be

reached via the IP address set.

Please note: However, this has not necessarily got to mean that the intended device can

be reached via this IP address!

More information on Parameter setting & configuration with PROFINET can be found in

the PROFINET communication manual , section "Establish online connection via PROFINET

using the Lenze »Engineer«"