3 can generator, 1 addresses, Can generator – Lenze Engineer v2.21 User Manual
Page 243: Error messages
Lenze · Engineer · 2.13 EN - 10/2014
243
Error messages
CAN generator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.3
CAN generator
12.3.1
Addresses
Invalid value range for addresses (min and max inverted?) [NWCAN0001]
Number of nodes for the network exceeded [NWCAN0002]
Node address for nodes beyond the value range [NWCAN0003]
Node address for node already exists [NWCAN0004]
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
In the CAN network, Settings tab, the minimum and
maximum addresses of the possible address range have
been inverted.
Accordingly alter the range, so that the minimum
address is smaller than the maximum address.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
More nodes than permitted in the "Settings" tab of the
CAN network are assigned to the CAN network.
• Remove nodes that are not required from the
network
or
• Increase the maximum permissible number of nodes
in the "Network/settings" tab.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
An invalid node address has been entered for the node
specified.
Change the node address so that it is within the
permissible value range.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
An already existing node address has been entered for
the node specified.
Change the node address so that a number is selected
that has not been allocated before.