5 transferring default values to the controller, Appendix – Lenze Engineer v2.21 User Manual
Page 300

Appendix
User motors
300
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.4.5
Transferring default values to the controller
If a controller has already been connected to a user motor in your project, the default values saved
in the motor can be transferred once again to the controller. This will reset settings that might have
been changed to the default values.
For this purpose, use the "Motor parameter" tab of the respective user motor.
How to transfer the default values to the controller:
1. Create an »Engineer« project including a user motor.
2. Highlight the user motor.
Area
Functions
Data and default values of the user motor
Parameters of the controller connected
Note!
• The button for transferring the default values is only activated if the controller group
suitable for the controller connected has been selected in the control field of the tab.
• If the drive controller is online at this point in time, the default values are transferred
to the offline and online values of the relevant codes of the drive controller.
• If the controller is in offline mode, the default values will be transferred to the offline
values of the controller codes in question.