Page 102: Device functions with active online connection, Stop

Device functions with active online connection
Application and parameter set transfer
102
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. If no online connection to the device has been established yet:
Click the
icon or select the menu command Online Go online to establish an online
3. Click the
icon or select the menu command Online Stop application.
4. Confirm the safety query on whether the application in the controller is to be stopped with
Yes.
• Then the application in the controller is stopped and controller inhibit is set.
• By clicking
or via the menu command Online Start application you can start the
application in the controller.
The application status is displayed in the status bar.
7.3
Application and parameter set transfer
If an online connection to the device has been established you can transfer the parameter set of the
device to the »Engineer« project, and vice versa. Furthermore you can transfer a (modified)
application from the »Engineer« to the device.
• The transfer functions can be executed via the Toolbar or the Online menu:
Order of data transfer to the device
The data transfer to the device is used to be carried out in the following sequence:
1. Stop devices: In this phase the data transfer is prepared, e.g. controllers are inhibited and
applications are stopped.
2. Transfer data: In this phase, the application, the parameters, and, if so, other data (e.g. cam
data) are transferred (depending on the command selected).
3. Start devices: In this phase the data transfer has been completed. Devices and applications are
started and controller is enabled.
Stop!
If a system module that contains several devices is selected instead of a device in the
Project view, the selected transfer function is executed with all the devices of the system
module to which an online connection has been established.
Icon
Menu command
Shortcut
Download program to device ( 103)
Download parameter set to device ( 105)