Manual control of the, Device functions with active online connection – Lenze Engineer v2.21 User Manual
Page 109
![background image](/manuals/566294/109/background.png)
Lenze · Engineer · 2.13 EN - 10/2014
109
Device functions with active online connection
Manual control of the motor direction of rotation: Rotating the axes manually
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5
Manual control of the motor direction of rotation: Rotating the axes manually
This function enables the axes to be rotated manually. This allows, for instance, for maintenance
work or diagnostics of the electrical connection.
• The respective axis can be simply rotated with the preset speed setpoint without the need of a
separate control program for motion control.
How to start the function:
Click
in the toolbar.
[7-1]
Example: Manual direction of rotation control with an 8400 TopLine C
Direction of rotation check for multi-axis systems
The direction of rotation control can be used for multi-axis systems with a controller that supports
this function (example: i700 servo inverter).
• The additional selection list serves to select the desired axis which is to be rotated manually.
• If, for instance, the direction of rotation control of Axis A is activated, the direction of rotation
control of the second axis can be activated in addition by selecting Axis B.
• Close the dialog window to deactivate the direction of rotation control in the previously
triggered axes.
Select the desired options:
• Speed: Determine setpoint
• Runtime: Determine period/time after
which the motor stops automatically.
Depending on the device, more options can be
available:
• Current: Enter value [A]
• Axis selection: For controllers which
support a double axis, you can select
between the axes Axis A/Axis B.
Start rotation of the motor: Click .
Stop rotation of the motor: Click .