2 baud rate and mmt master, Baud rate and mmt master, Error messages – Lenze Engineer v2.21 User Manual
Page 244
Error messages
CAN generator
244
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error during reading the address of nodes [NWCAN0005]
12.3.2
Baud rate and MMT master
Error during reading of node addresses [NWCAN0006]
Error during processing baud rate of object {0} [NWCAN0007]
No NMT master defined in the network! [NWCAN0008]
More than one NMT master defined in the network! [NWCAN0009]
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
A baud rate which is not supported has been set for the
node defined.
Set a different baud rate in the "Settings" tab of the
associated network.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
The access to the baud rate parameter has failed.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
In the indicated network no NMT master which transfers
the nodes to the Operational Mode has been defined.
Ignore warning if an external device takes over this
function.
Response (Lenze setting printed in bold)
Error Warning Information
Cause
Remedy
In the indicated network, several nodes have been
defined as NMT master. They switch the nodes to
Operational mode.
Ignore warning if this function is desired.