Raslog events – Brocade Network Advisor IP User Manual v12.3.0 User Manual
Page 928
![background image](/manuals/361713/928/background.png)
876
Brocade Network Advisor IP User Manual
53-1003153-01
Change tracking
24
NOTE
The Adaptive backup type is supported only on the Network OS devices; it is not supported
on the IronWare devices.
-
Startup Config Change Trap — Occurs when a startup configuration is changed.
-
Re-sync — Occurs when a trap is generated by the device during a startup or running
configuration change, or when a user performs a manual resynchronization of the device
For Network OS devices, Re-sync backup occurs after manual rediscovery of the VCS
cluster member device and when a CLI configuration deployment occurs on the product.
-
Manual — Occurs when a user clicks the Save Running/Startup Configuration button.
-
Scheduled — Occurs when backups are obtained as the scheduled times.
4. Perform one of the following actions:
•
Click the Refresh button to update the network and retrieve the latest data from the
database.
•
Click the View button to compare the contents of the latest configuration and the baseline
configuration. You can view only one configuration at a time.
•
Click the Export button to export the currently viewed change tracking records to a .csv file.
The default file name is “Change_Tracking_Report.csv.”
5. Click OK to save the configuration.
6. Click Cancel to exit the dialog box.
•
RASLog events
shows the supported events for Adaptive backup on Network OS devices.
TABLE 86
Configuration change events for Adaptive backup
Message ID
Type
Description
AG-1006
LOG
Access Gateway mode has been enabled or disabled.
AG-1020
LOG
Indicates that VF_Port-to-N_Port mapping has been changed because the
switch has come online or some new N_Port or VF_Port has come online.
AG-1041
LOG
Information that the specified port group has been deleted.
DCM-1001
LOG
Indicates that the VCS ID has been changed.
DCM-1009
LOG
Indicates that the RBridge ID has changed to the specified value.
DCM-1011
LOG
Indicates that the VCS mode has been enabled.
DCM-1012
LOG
Indicates that the VCS mode has been disabled.
DCM-1105
LOG
Indicates that the downloaded configuration file has been copied to the
current running configuration.
ELD-1001
LOG
Indicates that a loop has been detected by the Edge Loop Detection (ELD)
protocol on the specified interface. The interface has been shut down.
ELD-1002
LOG
Indicates that the interface on which a loop was detected has been
auto-enabled based on the configured shutdown time.
ESS-1008
LOG
Indicates that the specified fabric name has been configured or renamed.