Frame monitor, Chapter 35, Chapter 35, “frame monitor – Brocade Network Advisor IP User Manual v12.3.0 User Manual
Page 1239
![background image](/manuals/361713/1239/background.png)
Brocade Network Advisor IP User Manual
1187
53-1003153-01
Chapter
35
Frame Monitor
In this chapter
•
•
Creating a custom frame monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1189
•
•
Assigning a frame monitor to a port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1191
•
Finding frame monitor assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1192
•
Removing a frame monitor from a port . . . . . . . . . . . . . . . . . . . . . . . . . . 1192
•
Removing a frame monitor from a switch . . . . . . . . . . . . . . . . . . . . . . . . 1193
Frame Monitor
NOTE
Only available for Fabric OS products.
NOTE
Frame Monitoring is supported in Professional Plus and Enterprise Editions only. It is not supported
in the Professional Edition.
Frame monitors count the number of frames transmitted through a port that match specific values
in the first 64 bytes of the frame. Since the entire Fibre Channel frame header and many upper
protocol (for example, SCSI) headers fall within the first 64 bytes of a frame, frame monitors can
detect different types of traffic transmitted through a port. Each frame monitor keeps a timestamp
of its last refresh. It also keeps a generation count, which is incremented each time the monitor is
cleared.
Frame monitors generate alerts whenever the frame count for a certain frame type crosses the
threshold configured for that frame type. You can configure high thresholds for every frame type,
specify actions to be taken when the threshold is exceeded, and configure how often the data are
sampled.
Virtual Fabrics considerations: You can assign frame monitors to ports in a logical switch. If a port
is moved from one logical switch to another, however, all monitors that were assigned to the port
are cleared in the new logical switch.
Trunking considerations: For trunked ports, the frame monitor is configured on the trunk master.