beautypg.com

Or a, (ix/y+d), Operation, Description – Zilog EZ80F916 User Manual

Page 261: Condition bits affected attributes

background image

eZ80

®

CPU

User Manual

UM007715-0415

CPU Instruction Set

252

OR A, (IX/Y+d)

Logical OR

Operation

A  A OR (IX/Y+d)

Description

The (IX/Y+d) operand is an 8-bit value at the memory location specified by the contents

of the Index Register, IX or IY, added to the two’s-complement displacement d. This 8-bit

value is logically ORed to the contents of the accumulator, A. The result is written to the

accumulator.

Condition Bits Affected

Attributes

S

Set if result is negative; reset otherwise.

Z

Set if result is 0; reset otherwise.

H

Reset.

P/V

Set if parity is even; reset otherwise.

N

Reset.

C

Reset.

Mnemonic Operand

ADL Mode Cycle

Opcode (hex)

OR

A, (IX+d)

X

4

DD, B6, dd

OR.S

A, (IX+d)

1

5

52, DD, B6, dd

OR.L

A, (IX+d)

0

5

49, DD, B6, dd

OR

A, (IY+d)

X

4

FD, B6, dd

OR.S

A, (IY+d)

1

5

52, FD, B6, dd

OR.L

A, (IY+d)

0

5

49, FD, B6, dd

This manual is related to the following products: