beautypg.com

6 configuring the oam f5 loopback, 6 configuring the loopback mode -8, Configuring the oam f5 loopback – Nortel Networks 8000 User Manual

Page 420: Caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

10 Low-speed ATM configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

interface interface-type interface-number[.subinterface-number ]

The ATM interface view is displayed.

Step 3

Run:

oam

The OAM interface view is displayed.

A

CAUTION

Running the

insert

command can cause that the status of PVC turns Down. So, be

cautious to use this command.

When the OAM alarms occur on the upstream and downstream nodes of this connection,

you need not use the command of inserting the AIS/RDI cells on this connection point,

which easily causes that the OAM frequent alarm switching occurs on the upstream and

downstream nodes.

Step 4

Run:

insert vpi/vci { ais | rdi } { end | segment }

[ number ]

The AIS/ RDI cells are inserted.

Usually, the SR8000 sends the Alarm Indication Signal (AIS) cells only in the following

cases:

Receives the AIS cells.

The physical layer is faulty.

The ATM layer is faulty.

Not receives the CC cells continuously

The AIS cells can be inserted manually for the convenient debugging. The direct insertion of

the Remote Defect Indicator (RDI) cells is similar to that of the AIS cells.

Before running this command, you need not to configure the OAM attributes.

—End

10.10.6 Configuring the OAM F5 Loopback

Do as follows on the routers:

Step 1

Run:

system-view

The system view is displayed.

Step 2

Run:

interface atm interface-number[.subinterface ]

The ATM interface or the sub-interface view is displayed.

10-34

Nortel Networks Inc.

Issue 5.3 (30 March 2009)