Nortel Secure Router 8000 Series
Configuration -WAN Access
8 Frame relay configuration
8.5 Configuring frame relay LMI type and related
parameters
8.5.1 Establishing the configuration task
Applicable environment
If the LMI protocol is required to maintain the link status and the PVC status of FR and
optimize the running of the device, you need to configure the LMI type and related
parameters.
Preconfiguration tasks
Before configuring FR LMI type and related parameters, complete the following tasks:
•
Configuring physical parameters for Frame Relay interfaces
•
Configuring Frame Relay interfaces
Data preparation
To configure the FR LMI type and related parameters, you need the following data:
No
Data
1
FR interface number of a router and IP addresses to be allocated
2
Required n391, n392 and n393 parameters as well as polling interval on DTE
3
Required n392, n393 and t392 parameters on DCE
Configuration procedures
No.
Procedure
1
Configuring frame relay LMI and related parameters of DTE
2
Configuring frame relay LMI and related parameters of DCE
3
8.5.2 Configuring frame relay LMI and related parameters of DTE
Do as follows on the routers:
Step 1
Run:
system-view
The system view appears.
Step 2
Choose one of the following steps to enter the corresponding interface view as required.
Issue 5.3 (30 March 2009)
Nortel Networks Inc.
8-21