Nortel Secure Router 8000 Series
Configuration -WAN Access
7 LAPB and X.25 configuration
•
x25 call-facility threshold
in out
•
x25 map
{
compressedtcp
protocol-address
|
ip
protocol-address
} *
x121-address
x.121-address
threshold
in out
Step 13
Run one of the following commands to carry transmitting delay request in a call.
•
x25 call-facility send-delay
milliseconds
•
x25 map
{
compressedtcp
protocol-address
|
ip
protocol-address
} *
x121-address
x.121-address
send-delay
milliseconds
Step 14
Run one of the following commands to enable Recognized Operating Agency (ROA).
•
x25 call-facility roa-list
name
•
x25 map
{
compressedtcp
protocol-address
|
ip
protocol-address
} *
x121-address
x.121-address
roa-list
name
Step 15
Run one of the following commands to enable the sending of broadcast datagrams to the VC
associated with the specified address.
•
Run the
x25 map
{
compressedtcp
protocol-address
|
ip
protocol-address
} *
x121-address
x.121-address
broadcast
command to send broadcasting datagrams to the
peer of the SVC associated with this address mapping.
•
Run the
x25 pvc
pvc-number
{
compressedtcp
protocol-address
|
ip
protocol-address }*
x121-address
x.121-address
broadcast
command to send broadcasting datagrams to the
peer of this PVC.
Step 16
Run:
x25 queue-length queue-size
The command configures the length of X.25 VC queue.
Step 17
Run:
x25 map { compressedtcp protocol-address | ip protocol-address } * x121-address
X.121-address no-callout
Calls cannot be initiated by this address mapping.
Step 18
Run:
x25 map { compressedtcp protocol-address | ip protocol-address } * x121-address
X.121-address no-callin
Calls initiated from this address mapping cannot be received.
By default, the value of SVC maximum idle time is 0 minute. One address mapping is
associated with only one VC. The number of pre-acknowledged packets is 0.
--- End
The X.25 of the SR8000 allows the addition of some additional characteristics, including a
series of optional user facilities stipulated in ITU-T Recommendation X.25 to improve
performance or broaden the application.
This section shows how to configure additional characteristics, including the options in the
x25 map
....... and the
x25 pvc
.............. commands. Select and configure these additional
characteristics according to actual needs, X.25 network structure, and the available services
provided by service providers.
Issue 5.3 (30 March 2009)
Nortel Networks Inc.
7-27