7 LAPB and X.25 configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

Step 5

Run:

x25 vc-range[ in-channel Hc hic ]

[ bi-channel Itc htc ]

[ out-channel loc hoc ]

The command configures the X.25 VC range.

Step 6

Run:

x25 modulo { 8 | 128 }

The command configures packet sequence numbering mode.

By default, an X.25 interface uses modulo 8.

Step 7

Run:

x25 window-size input-window-size output-window-size

The command configures the size of receiving window and that of sending window of VC.

By default, the size of receiving window and that of sending window are both 2.

Step 8

Run:

x25 packet-size input-packet output-packet

The command configures the maximum size of packets received and sent.

By default, the maximum size of both received packets and sent packets are 128.

Step 9

Choose one of the following commands to validate the configuration.

Run the

shutdown

and the

undo shutdown

command.

Run the

restart

command.

CD NOTE

After the configuration of Step 5 to Step 8, you must perform Step 9 to validate the configuration.

—End

Setting X.25 operation mode

SR8000 supporting layer 3 of X.25 can work in either DTE mode or in DCE mode. You can

also specify the format for the datagram, and the selective formats are IETF and nonstandard.

Note that an X.25 public packet switching network requires routers to access the network as

DTE. You also need to encapsulate DTE with the IETF format in normal circumstances

making the operating mode of X.25 DTE and the encapsulation format as IETF.

If the data transmits by connecting a pair of serial interfaces on the two routers back to back,
ensure that the two ends are DTE and DCE respectively and the format of the packet is
consistent.

Setting the X.121 address of the interface

If the SR8000 uses X.25 switching, you can skip this task. If they connect to X.25 public

packet network, you must set an address for the connected X.25 interface according to the
requirements of the ISP (Internet Service Provider).

7-14

Nortel Networks Inc.

Issue 5.3 (30 March 2009)