Working with a redundant at-cv5m01 management card – Allied Telesis AT-S70 User Manual
Page 83

AT-S70 Management Software User’s Guide
83
Port
Identifies the port on the module.
Link
Displays the status of the link state on the port.
Online - Indicates there is a valid link.
Offline - Indicates there is no link.
Speed
Displays the operating speed of the port. Possible values are Auto,
10M or 100M.
Mode
Displays the duplex mode of the ports. Possible values are:
Auto - The port is auto-negotiating with the connected device to
automatically configure to the highest common setting.
Full - The port can send and receive data simultaneously.
Half - The port can send or receive data, but not both at the same
time.
Reset CPM and Restart System Software
Resets the settings of the Management Card and restarts the system.
Refer to “Resetting the AT-CV5M01 Management Card” on page 84.
4. From the Main Menu, select System Configuration.
The System Configuration Menu is displayed, as shown in Figure 10
on page 46.
5. From the System Configuration Menu, select Save Configuration
File.
Working with a
Redundant
AT-CV5M01
Management
Card
The AT-CV5M01 Management Card is the CPU subsystem for the
AT-CV5000 and AT-CV1200 chassis. The AT-CV5M01 Management Card
provides management capability to configure and monitor the status of the
converter line cards.
Only one management card is needed to provide management capabilities
to the converter line cards. However, a second management card can be
installed in the chassis to function as a redundant management card.
To switch over to the redundant management card, perform the following
procedure:
1. From the Main Menu, select Administration.
The Administration Menu is displayed, as shown in Figure 6 on page
38.
2. From the Administration Menu, select CPM Switch Over.