Appendix B: DIP Switch Settings

272

AT-CM70S Line Card DIP Switch

The AT-CM70S line card features one set of DIP switches located on the
base board and labeled “SW1”, as shown in Figure 92.

Figure 92. DIP Switch Set on an AT-CM70S Line Card

The DIP switches in the SW 1 DIP switch set allow you to set the
operating mode of the line card. For information about the operating
modes, refer to “Configuring the Line Card Operating Mode” on page 67,
and for information about OAM, refer to Chapter 8, “Operations,
Administration, and Maintenance (OAM)” on page 111.

Table 10 shows how to enable the operating mode on an AT-CV1KSS line
card by setting the DIP switches in the SW 1 DIP switch set.

“X” means that the DIP switch position can be ON or OFF.

AT-CM70S

LK OAM

S
F
P

1

T1/E1

1

2

ON

SW 1 DIP Switch Set

Table 10. SW 1 DIP Switch Set (Operating Mode) for the AT-CM70S Line

Card

Operating Mode

DIP 1

DIP 2

Link Test (non-OAM)

OFF

X

OAM Bypass

ON

OFF

OAM Visible

ON

ON

Manufacturing Default Settings

OFF

OFF